Capabilities / Heat Treatment
Heat Treatment
Calibrated furnaces and agitated quenching lock in mechanical and corrosion properties.
3 × 1.5 TFurnaces
1:15Quench ratio
Three oil-fired furnaces, 1.5 tonnes each, with 2-point digital control and paperless chart recorders for full traceability. Multi-step gradient cycles are used for Duplex and Super Duplex grades. Calibration follows ASTM A991, API 6D Annex H and API 6A Appendix M. Quenching uses a 1:15 water tank with vigorous stirring and cooling-tower control.